Wuhan Global Metal Engineering Co., Ltd
The pioneer manufacturer of heaters & sensors
Place of Origin: | China |
Brand Name: | GME |
Certification: | CE, ROHS |
Minimum Order Quantity: | 5pcs |
---|---|
Packaging Details: | Standard export packing |
Delivery Time: | 1 month |
Payment Terms: | T/T, Western Union |
Supply Ability: | 2000 Piece/Pieces per Week |
Rated Voltage: | 180V AC -240V AC 50HZ | Power Consumption: | 2.5W |
---|---|---|---|
Accuracy Class: | ±0.5%FS | Work Environment: | Temperature: 0°C ~50°C, RH: 35%~85% |
Display Accuracy: | 0.1°C | Connection Methods: | Terminal |
Highlight: | thermostat temperature controller,hot runner temperature controller |
Rated voltage | 180V AC -240V AC 50HZ | Power Consumption | 2.5W |
Accuracy class | ±0.5%FS | Work environment |
Temperature: 0°C ~50°C, RH: 35%~85% |
Display accuracy | 0.1°C | Connection methods | Terminal |
Color: | black |
Packaging Details: | in Cartons |
Delivery Detail: | 1 -15 days |
XMT 2C Series Temperature Controller: uses SCM to control the circuit. Analog IC uses multiple filter and high accuracy amplifier. PID and self tuning function are programmed in software. We choose high quality components for the meter as well. All these endow the meter high performance in control.
2. Product Model:
XMT 1 - 2 3 4 5 - 6 7 8 9 10 11 12
SN | Name | Explanation |
1 |
Outer Dimension (mm) |
A: 48X48X85 B: 48X96X82 C: 96X48X82 D: 72X72X82 E: 96X96X82 G: 160X80X70 |
2 | Design Code | 2C: 2C series product |
3 | Control Methods | 0: PID control 1: step control |
4 | Input Methods | 1: Thermocouple 2: RTD |
5 | Output Methods | 1: Break Output 2: Continuous Output |
6 | Refrigerating Methods |
0: No Refrigerating 1: Step Refrigerating 2: Proportional Refrigerating 3: PID Refrigerating |
7 | Alarm Methods | 0: No alarm 1: upper limit upward alarm 2: lower limit downward alarm 3: upper/lower limit alarm 4: lower limit upward alarm 5: upper & lower limit alarm 6: upper/lower limit upward alarm 7: lower limit downward keep alarm 8: absolute value alarm 9: upper & lower limit keep alarm |
8 | Input Type | 1: K 2:E 3:S 4:Pt100 5: Cu50 6:J |
9 | Output Type |
1: relay contact switch output 2: logic electrical level output (to control SSR) 3: single phase SCR Zero-crossing trigger outputto control thyristor 4: 4-20mA current output 5: 0-5V voltage output 6: 0-10V voltage output 7: phase shift trigger SCR 8: 0-10mA current output |
10 | Refrigerating Type | 0: no refrigerating output 1: relay contact switch output 2: logic level output (used to control SSR) 3: single-phase SCR zero-crossing trigger output (used to control thyristor) |
11 | Alarm Type | 0: no refrigerating output 1: relay contact switch output 2: logic level output (used to control SSR) 3: single-phase SCR zero-crossing trigger output (used to control thyristor) |
12 | Temperature range (°C) | 1: 0-100 2:0-150 3:0-400 4 : 0-600 5:0-800 6:0-999 7:0-99.9 |